IS international standard type single-stage single suction centrifugal pump water Introduction
Date:2016/6/12 Number:6943

With international standard IS type single-stage single-suction clean water centrifugal pump for conveying water and physical and chemical properties similar to water temperature does not exceed 80 ℃ or liquids. This series of pump structure is simple, stable performance, low noise, small vibration, low NPSH, easy maintenance, suitable for industrial, urban drainage, agricultural irrigation.

    Product performance standards: GB / T5657-1995, closer to the international design based on performance and size ISO2858 international standard regulations, technical standards, products reach the international advanced level, it is one of our energy-saving products to promote.

IS pump wide versatility, rapid supply of spare parts. Full range consists of more than 140 kinds of specifications, only divided into four series, namely four kinds of shafts and bearings, bushings, suspension (bearing body), etc., high degree of common parts.

   Conditions of Use:

Suction pipe inlet pressure ≤0.5Mpa, pump the maximum working pressure ≤1.6Mpa

Particle-free liquid temperature does not exceed 80 ℃ water or physical and chemical properties similar to water: media

Environment: Humidity ≤95%, temperature ≤45 ℃

Model significance:

IS 100 ---- 80 ---- 160 A (B, C)

   Pump model inlet diameter outlet diameter of the impeller diameter through the first impeller (II) cuts

 

Pump unit installation:

Pump installation have a significant impact on the quality of the operation and life of the pump, the installation and calibration must.

1, the base horizontally placed on the ground, with a bolt lock.

2. Check and adjust the pump and motor shaft coaxial line, coupling the upper and lower outer circle around the difference shall not exceed 0.1mm, left two coupling end clearance of 2-3mm and round shaft gap the difference is not more than 0.3mm.

   3, pump water pipe diameter should be appropriately increased, in order to reduce water losses and taper pipe and pump water flange connection.

   4, the pipe may not be directly added to the weight of the pump, must use a special support line

Longyan City, Kowloon Pump Manufacturing Co., Ltd. specializing in the production: to provide one-stop fire pumps, multistage centrifugal pumps, fire pumps, single-stage centrifugal pumps, centrifugal pumps, fire pump manufacturers, pump plant in Fujian, fire pump prices, vertical multistage centrifugal pumps, multi-stage fire pump, water pump factory in Kowloon, Longyan fire pumps, fire pumps manufacturers, submersible pumps, sewage pumps, vertical multistage centrifugal pump manufacturers, pump manufacturers, pump manufacturers in Fujian, Longyan pump plant (former state enterprises Longyan pump plant restructuring) enterprise official website: http://www.clairvoyantmediumaberdeen.com    more product information please contact us